With the introduction of its CNX system, Fluke proposes a new approach to control electrical installations in cases (a little complex) when it is necessary to perform several measurements simultaneously, which is moreover in spaced points. With the CNX 3000, measurement modules located at the points to be controlled transmit by radio (with a range of 20 m) their measurements to a centralizing device, which can be a multimeter FLK-CNX3000 (which can receive measurements of three wireless modules) or a PC equipped with PC3000 software (which can process up to 10 simultaneous measurements).
- Multimeter and measurement modules compliant with Safety Standards Category III 1000 V and Category IV 600 V
- Record up to 65,000 Min/Max/Moy measurement points in one or more recording sessions
- Recording interval set up from 1 second to 1 hour
- Specifications of the main elements of the CNX3000 range:
CNX 3000 digital multimeter: up to 1000V, 400 mA, 600 ohms, 10 mF, 100 kHz. Dimensions (HxLxP): 4.75×9.3×20.7 cm
CNX v3000 module, AC voltage measurement up to 6 kV, 45 Hz to 1 kHz
CNX a3000 module, true effective AC current clip up to 400 A, 100 Hz to 500 Hz, 2000-point display
CNX i3000 iFlex module, true effective AC current clip with iFlex flexible sensor: up to 2500 A, 2000-point display
CNX t3000 module, type K thermocouple (-200 degrees Celsius at 1372 degrees Fahrenheit), 2000-point display
Find out more: https://www.fluke.com/fluke/frfr/products/testeurs-sans-fil